3. Drive-Source Recovery Request and Operation-Pause Reset Request


(1) Drive-source recovery request

1. How to request a drive-source recovery

A drive-source recovery request can be issued using one of the following methods:

 Set I/O parameter No. 44 to “1” (Input selection function 014 = Drive-source cutoff reset input),

then input the ON edge to input port No. 14.

 Select [Drive-Source Recovery Request (P)] from the [Controller (C)] menu on the PC software

screen.

 Select Ctl (controller operation) and RPwr (drive-source recovery request) on the mode selection

screen of the teaching pendant.

2. Case where a drive-source request is required

A drive-source recovery request is required in the following case:

 A drive-source cutoff factor occurred when I/O parameter No. 44 was set to “1”  Recovery after

the cutoff factor is removed.


(2) Operation-pause reset request

1. How to request an operation-pause reset

An operation-pause reset request can be issued using one of the following methods:

 Set I/O parameter No. 35 to “1” (Input selection function 005 = Operation-pause reset signal),

then input the ON edge to input port No. 5.

 Select [Operation-Pause Reset Request (L)] from the [Controller (C)] menu on the PC software

screen.

 Select Ctl (controller operation) and RAct (operation-pause reset request) on the mode selection

screen of the teaching pendant.

2. Cases where an operation-pause reset request is required

An operation-pause reset request is required in any of the following cases:

 The automatic operation was stopped using the deadman switch when other parameter No. 9

was set to “2” (Deadman-switch recovery type = Continued operation) (only during automatic
operation)

 Recovery (reset of operation pause) after the stop is reset.

 An emergency stop was actuated during automatic operation when other parameter No. 10 was

set to “2” (Emergency-stop recovery type = Continued operation) (only during automatic
operation)

 Recovery (reset of operation pause) after the emergency stop is reset.

 The safety gate was opened during automatic operation when other parameter No. 11 was set to

“2” (Safety-gate open recovery type = Continued operation) (only during automatic operation)

Recovery (reset of operation pause) after the safety gate is closed.

 An OFF-level input signal was received by input port No. 6 when I/O parameter No. 36 was set

to”1” (Input selection function 006 = Operation-pause signal)

 Recovery (reset of operation

pause) after an ON-level input signal is received by input port No. 6.

* If the case in 2 of (1) and any of the cases in 2 of (2) are present at the same time, a drive-source

recovery request must be issued first, followed by an operation-pause reset request.