36

Part 1 Installation

INTELLIGENT ACTUATOR


Terminal Numbers and Descriptions of Safety I/O Terminals

Terminal number

Description

1

(When the ANSI-compatible teaching pendant SEL-TD and IA-T-
XA are used)
Contact output 2 for deadman switch 2 on the teaching pendant

2

(When the ANSI-compatible teaching pendant SEL-TD and IA-T-
XA are used)
Contact output 1 for deadman switch 2 on the teaching pendant

3

(When the ANSI-compatible teaching pendant SEL-TD and IA-T-
XA are used)
Contact output 2 for emergency-stop switch 2 on the teaching
pendant

4

(When the ANSI-compatible teaching pendant SEL-TD and IA-T-
XA are used)
Contact output 1 for emergency-stop switch 2 on the teaching
pendant

5

Contact output 2 for deadman switch 1 on the teaching pendant

6

Contact output 1 for deadman switch 1 on the teaching pendant

7

Contact output 2 for emergency-stop switch 1 on the teaching
pendant

8

Contact output 1 for emergency-stop switch 1 on the teaching
pendant

9

Enable input to the X-SEL controller
(Closing pins 10 and 9 will enable the controller operation.)

10

24-V power output from the X-SEL controller
(Do not connect to pin 12.)

11

Emergency-stop input to the X-SEL controller
(Opening pins 12 and 11 will actuate an emergency-stop.)

12

24-V power output from the X-SEL controller
(Do not connect to pin 10.)










12 1