Part 4 Commands

INTELLIGENT ACTUATOR



ARCC (Move along arc via specification of center position and center angle (arc interpolation))

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

ARCC

Center

position

number

Center

angle

PE

[Function] Move along an arc originating from the current position by keeping a specified radius from the

center position, via arc interpolation.
Specify the center position in operand 1, and the center angle formed by the position origin
and end position in operand 2. The center angle is set in a range from –3600 to 3600 degrees
(±10 revolutions). A positive value indicates CCW (counterclockwise-direction) movement,
while a negative value indicates CW (clockwise-direction) movement (setting unit: degree).

(Note)

The rotating direction along the actual operation locus may vary depending on how the axes
are installed and combined. Be sure to confirm the rotating direction by test operation.
The center angle is set in degrees and may include up to three decimal places.


The speed and acceleration will take valid values based on the following priorities:

Priority Speed

Acceleration (deceleration)

1

Setting in the position data
specified in operand 1

Setting in the position data specified in operand 1

2

Setting by VEL command

Setting by ACC (DCL) command

3

Default acceleration in all-axis parameter No. 11
(Default deceleration in all-axis parameter No. 12)

If speed is not set, a “C88 speed specification error” will generate.
If acceleration/deceleration is not valid, a “C89 acceleration/deceleration specification error”
will generate.












(Note 1)

This command is valid on arbitrary orthogonal planes. (Axis 2 may be selected automatically
prior to axis 1 in accordance with the position data.)

(Note 2)

If the center angle is small and the locus runs near a soft limit, “Error No. C73, “Target-locus
soft limit over” may occur. In this case, set the locus slightly on the inside of the soft limit
boundary or make other corrections. Note that the larger the center angle, the smaller the
locus error becomes.


[Example]

VEL

100

Set the speed to 100 mm/sec.

ARCC

100

120

Move along an arc from the position origin for a center angle
of 120 degrees around position No. 100 being the center
(CCW direction).

Position origin

Center angle

Center position