PAPR (Set push-motion approach distance, speed)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

PAPR

Distance

Speed CP

[Function] Set the operation to be performed when a PUSH command is executed.

Set the distance (push-motion approach distance) over which push-motion approach
operation (torque-limiting operation) will be performed in operand 1 (in mm), and set the
speed (push-motion approach speed) at which push-motion approach operation (torque-
limiting operation) will be performed in operand 2 (in mm/sec).
The push-motion approach distance specified in operand 1 may contain up to three decimal
places, while the speed specified in operand 2 cannot contain any decimal place.























[Example]

PAPR

100

30

Set the push-motion approach distance in a PUSH
command to 100 mm and the push-motion approach speed
to 30 mm/sec.

MOVP

2

Move to position No. 2.

PUSH

10

Perform push-motion operation from position Nos. 2 to 10.

(Note)

When the OVRD command is used, the push-motion approach speed is clamped at the
lower-limit speed of 1 mm/sec. (Reliable push-motion operation cannot be guaranteed at the
lower-limit speed. Whether or not push-motion operation can be performed reliably must be
confirmed on an actual machine by considering the effects of mechanical characteristics, etc.,
at low-speed push-motion approach.)

Y-axis

Position origin

Push-motion approach distance

Target position

X-axis

Start position of push-motion approach operation
(torque-limiting operation)