IAI America XSEL-KET User Manual

Page 59

Advertising
background image

40

Part 1 Installation

INTELLIGENT ACTUATOR


(4) Operations to Safety I/O Terminals and X-SEL Controller Conditions

1) X-SEL Controller Conditions upon Opening/Closing Safety I/O Terminal Pins 9 and 10 (Enable

Input and 24 V to X-SEL Controller)

Connection of teaching pendant to relay box

Not connected

Condition of AUTO/MANU switch on X-SEL unit

AUTO

MANU

Condition of pins 9 and 10

open

close

open

close

X-SEL condition (without dummy plug)

Ardy

Ardy

dSF

rdy

X-SEL condition (with dummy plug)

Ardy

Ardy

dSF

rdy

Connection of teaching pendant to relay box

Connected

Condition of AUTO/MANU switch on X-SEL unit

AUTO

MANU

Condition of pins 9 and 10

open

close

open

close

X-SEL condition

Ardy

Ardy

dSF

rdy

(Note)

Set the knob of the controller's mode switch and that of the AUTO/MANU selector switch to
the same side.



2) X-SEL Controller Conditions upon Opening/Closing Safety I/O Terminal Pins 11 and 12

(Emergency-Stop Input and 24 V to X-SEL Controller)

Connection of teaching pendant to relay box

Not connected

Condition of AUTO/MANU switch on X-SEL unit

(Note)

AUTO MANU

Condition of pins 11 and 12

open

close

open

close

X-SEL condition (without dummy plug)

Ardy

Ardy

EMG

rdy

X-SEL condition (with dummy plug)

EMG

Ardy

EMG

rdy

Connection of teaching pendant to relay box

Connected

Condition of AUTO/MANU switch on X-SEL unit

AUTO

MANU

Condition of pins 11 and 12

open

close

open

close

X-SEL condition

EMG

Ardy

EMG

rdy

(Note)

Set the knob of the controller's mode switch and that of the AUTO/MANU selector switch to