Chapter 4 name and function of each part, Front view of controller, Chapter 4 – IAI America XSEL-KET User Manual

Page 28: Name and function of each part

Advertising
background image

9

INTELLIGENT ACTUATOR

Part 1 Installation


Chapter 4 Name and Function of Each Part


1. Front View of Controller


4-axis type


























(1) FG

terminal

This terminal is used to ground FG on the enclosure. The enclosure is
connected to PE in the AC input part inside the controller.


FG Terminal Specifications

Item Overview

M4 3-point SEMS screw, 5 mm

Cable size

2.0 ~ 5.5 mm

2

Grounding method

Class D grounding


(2) Fuse

holder

This half-cut fuse holder is used to protect overcurrent in the AC control-
power input part.

It prevents inflow of abnormal current generated by ground fault, etc., and
uses a slow-blow fuse specified by IAI.

Overview of Fuse Holder Specifications

Item Description

Holder

F-220-01A2 by Sato Parts

Fuse type

SG5013 3.15 by Sky Gate

Melting characteristics

Time lag type

CONTROLLER

RB

C.POWER

M.POWER

FUSE

M4

LS4

M3

LS3

M2

LS2

M1

LS1

PG1

BK1

PG2

BK2

PG3

BK3

PG4

BK4

I/O1

I/O2

I/O3

I/O4

CODE

HOST

TP

MODE

(5)

(6)

(11) (12) (13) (14)

(15)

(16)

(17)

(1)

(2) (3) (4) (8)

(9)

(10)

(18)

(19)

Advertising