(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
B1F
Ethernet job busy error
An attempt was made to start a new processing when an Ethernet mailbox
control job was busy.
B20
Ethernet uninitialized device use error
An attempt was made to use the Ethernet system when initialization of the
Ethernet device was not yet complete. Check the I/O parameter Nos. 123 to
159, 14, 15, etc. according to the application purpose.
B21
Ethernet IP address error
In a normal condition of use, an error will generate under the following
conditions:
The conditions under which an error will generate when the IP address (H) (first
octet) through IP address (L) (fourth octet) are expressed as IP_H, IP_MH,
IP_ML, IP_L are as follows:
IP_H
O or IP_H = 127 or IP_H > 255
or IP_MH < 0 or IP_MH > 255
or IP_ML < 0 or IP_ML > 255
or IP_L
0 or IP_L 255
Among others, check the IP address of the connection destination in the integer
variable specified by I/O parameter Nos. 132 to 135, 149 to 152 and 154 to 157
or by an IPCN command.
B22
Ethernet port number error
An error will generate if “Own port number < 1025” or “Own port number >
65535” or “Own port number duplicated” or “Port number of connection
destination (client)
0” or “Port number of connection destination (client)) >
65535” or “Port number of connection destination (server) < 0” or “Port number
of connection destination (server) > 65535” is satisfied.
Among others, check the port number of the connection destination in the
integer variable specified by I/O parameter Nos. 144 to 148, 159, 153 and 158
or by an IPCN command.
C02
Maximum number of running programs over error
A request was made to execute programs exceeding the number of programs
that can be executed simultaneously.
C03
Non-registered program specification error
An unregistered program number among Nos. 1 to 64 was specified by a PIO or
in the program.
C04
Program entry point non-detection error
A request was made to execute a program number for which no program steps
are registered.
C05
Program first-step BGSR error
The program specified for execution starts with BGSR.
C06
Executable step non-detection error
The program specified for execution does not contain executable program
steps.
C07
Subroutine non-definition error
The subroutine specified for call is not defined.
C08
Subroutine duplicate-definition error
The same subroutine number is defined at multiple locations.
C0A
Tag duplicate-definition error
The same tag number is defined at multiple locations.
C0B
Tag non-definition error
The tag specified as the jump destination of a GOTO statement is not defined.