381


(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

813

Maintenance information 3

Maintenance information (for analysis)

814

Maintenance information 4

Maintenance information (for analysis)

815

Maintenance information 5

Maintenance information (for analysis)

900

Blank step shortage error

There are not enough blank steps to save step data. Provide enough
blank steps needed to save step data.

901

Step number error

The step number is invalid.

902

Symbol-definition table number error

The symbol-definition table number is invalid.

903

Point number error

The point number is invalid.

904

Variable number error

The variable number is invalid.

905

Flag number error

The flag number is invalid.

906

I/O port/flag number error

The I/O port/flag number is invalid.

910

Command error (IAI protocol HT reception)

The command ID is not supported or invalid. (For future extension)

911

Message conversion error (IAI protocol HT reception)

The transmitted message does not match the message format or
contains invalid data. (For future extension)

912

PC/TP servo-movement command acceptance-enable input
OFF error

Any axis movement command issued to the axis specified in I/O
parameter No. 78 from the PC/TP will not be accepted while the input
port specified in I/O parameter No. 77 is OFF. (Important: The
acceptance-enable input port will become invalid once the operation is
started.)

A01

System-memory backup battery voltage-low warning

The voltage of the system-memory backup battery is low. Replace the
battery. (Level voltage where data backup can be performed)

A02

Abnormal system-memory backup battery voltage

The voltage of the system-memory backup battery is low. Replace the
battery. (Level voltage where data backup cannot be performed)

A03

Absolute-data backup battery voltage-low warning (Driver
analysis)

The voltage of the absolute-data backup battery is low. Check the
battery connection or replace the battery.

A04

System mode error at core update

An update command was received when the system was not in the
core update mode. Before updating the core, confirm that a chip
resistance for setting core update mode is provided on the board. (For
maintenance)

A05

Motorola S record format error

The update program file is invalid. Check the file.

A06

Motorola S checksum error

The update program file is invalid. Check the file.

A07

Motorola S load address error

The update program file is invalid. Check the file.

A08

Motorola S write address over error

The update program file is invalid. Check the file.

A09

Flash-ROM timing limit over error (Write)

Error writing the flash ROM

A0A

Flash-ROM timing limit over error (Erase)

Error erasing the flash ROM

A0B

Flash-ROM verify error

Error erasing/writing the flash ROM

Advertising