IAI America XSEL-KET User Manual

Page 405

Advertising
background image

Appendi

x

INTELLI

GENT A

CTUAT

OR

386

(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

B00

SCHA setting error

The setting of SCHA command is invalid.

B01

TPCD setting error

The setting of TPCD command is invalid.

B02

SLEN setting error

The setting of SLEN command is invalid.

B03

Home-return method error

The setting of “Axis-specific parameter No. 10, Home-return method” is invalid.
(Not incremental encoder AND current position 0 home is specified, etc.)

B04

1-shot-pulse output excessive simultaneous use error

The number of BTPN and BTPF timers operating in one program simultaneously
exceeds the upper limit (16).

B05

Estimate-stroke over error at home return

The operation at home return exceeded the estimate stroke. The home sensor
or creep sensor may be faulty, among other reasons.

B06

Expanded-SIO in-use error

An attempt was made to open a channel already opened by other task.

B07

Expanded-SIO unopen error

An attempt was made to use a channel not opened by own task.

B08

Expanded-SIO duplicate WRIT execution error

WRIT commands were executed simultaneously by multiple tasks for the same
channel.

B09

Expanded-SIO RS485 WRIT/READ simultaneous execution error

WRIT and READ commands were executed simultaneously in the RS485 mode.

B0A

Expanded-SIO unassigned-channel use error

An attempt was made to use a channel not assigned properly. Check I/O
parameter Nos. 100 to 111 and the statuses of I/O slots.

B10

Phase-Z search timeout error

Phase Z cannot be detected. Check for operation restriction, wiring, encoder,
motor, etc.

B11

Home-sensor pull-out timeout error

Pull-out from the home sensor cannot be confirmed. Check for operation
restriction, wiring, motor, home sensor, etc.

B12

Storage variable number error for SEL command return code

Invalid number of the variable that stores the code returned by the SEL command

B13

Backup SRAM data checksum error

The backup SRAM data has been destroyed. Check the battery.

B14

Flash-ROM, 8-Mbit version unsupported function error

An attempt was made to use a function not supported in the flash-ROM, 8-Mbit
board environment.
(HT connection specification, etc.)

B15

Input-port debug filter type error

The setting of input-port debug filter type is invalid.

B16

SEL operand specification error

The operand specification of SEL command is invalid.

B17

Parameter register busy error at issuance of slave command

The driver special command ACK generated a timeout at issuance of a slave
command.

B18

Device number error

The device number is invalid.

B19

Unit type error

The unit type is invalid

B1A

Absolute reset specification error

The specification for absolute reset using an optional function, etc., is invalid.
(Two or more axes are specified simultaneously, non-absolute-encoder axis is
specified, etc.)

B1B

Ethernet “opening socket without closing” error

An attempt was made to open a socket again without closing it first.

B1C

Ethernet “other task in use” error

An attempt was made to open again a channel which is already open in other
task.

B1D

Ethernet non-open error

An attempt was made to use a channel not yet opened in the applicable task.

B1E

Ethernet multiple WRIT execution error

WRIT commands were executed simultaneously to the same channel in multiple
tasks.

Advertising
This manual is related to the following products: