IAI America XSEL-KET User Manual

Page 372

Advertising
background image

353

Appendix

INTELLIGENT ACTUATOR


Axis-Specific Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

78 Maximum

takeoff

command amount

0

-3000 ~ 3000

0.001 mm

Maximum lift command amount before brake
unlock (Input with sign)
(Suppression of momentary drop upon servo ON
when a heavy object is placed)
* Important: Input using the same sign as the

rising coordinate direction. (0.100 mm to 0.500
mm in absolute value as a guideline)

* The servo-ON check time (axis-specific

parameter No. 30) must also be extended
(approx. 1000 to 1500 msec) to provide a
sufficient time for rise-direction torque to follow.
(Valid with main application version 0.25 or
later. With version 0.26 or later, this setting is
valid only when a brake is equipped.)

79

Actual takeoff check
distance

5

0 ~ 3000

0.001 mm

Absolute value input (Main application version
0.26 or later)

80 Maximum

forced-feed

range

0

0 ~ 9999

0.001 mm

For reduction of settling time. (Invalid range if “0”
is set) (Approx. 1.000 mm as a guideline)
(Available with main application version 0.28 or
later)

81 Minimum

forced-feed

range

200

0 ~ 9999

0.001 mm

(Available with main application version 0.28 or
later)

82 Medium

forced-feed

range

600

0 ~ 9999

0.001 mm

(Available with main application version 0.28 or
later)

83

Absolute synchro slave-
axis initialization
cancellation

0

0 ~ 5

Valid only with a synchro slave axis. (Main
application version 0.31 or later)

84 Maximum

synchronization
correction speed of
synchro slave axis

5

0 ~ 100

mm/sec

Maximum travel speed for synchronization
position correction of slave axis. Valid only with a
synchro slave axis. * Note: Not limited by the
safety speed. (Main application version 0.40 or
later)

85 Home-return

acceleration/deceleratio
n

15

1 ~ 300

0.01 G

(Main application version 0.41 or later)

86

Zone 1 MAX

0

-99999999 ~

99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

87

Zone 1 MIN

0

-99999999 ~

99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

88

Zone 1 output number

0

0 ~ 899

Physical output port or global flag (Output is
invalid if “0” is input; multiple specification is
invalid) (“0” can be input in PC software version
1.0.0.0 or later or TP application version 1.06 or
later)

89

Zone 2 MAX

0

-99999999 ~

99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

90

Zone 2 MIN

0

-99999999 ~

99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

91

Zone 2 output number

0

0 ~ 899

Physical output port or global flag (Output is
invalid if “0” is input; multiple specification is
invalid) (“0” can be input in PC software version
1.0.0.0 or later or TP application version 1.06 or
later)

92

Zone 3 MAX

0

-99999999 ~

99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.

93

Zone 3 MIN

0

-99999999 ~

99999999

0.001 mm

Valid only when MAX > MIN. * Must be inside the
range for at least 3 msec.