Part 4 commands – IAI America XSEL-KET User Manual
Page 115
96
INTELLIGENT ACTUATOR
Part 4 Commands
2. In Alphabetical Order
Operation type in the output field
CC: Command was executed successfully,
ZR: Operation result is zero, PE: Operation is complete,
CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1
Operand 2,
GT: Operand 1 > Operand 2, GE: Operand 1
Operand 2,
LT: Operand 1 < Operand 2, LE: Operand 1
Operand 2
Command
Page
Condition
Operand 1
Operand 2
Output
Function
A
ABPG 132
Optional
Stop
program
number
(Stop program number)
CC
Stop other program
ACC 142
Optional
Acceleration
Prohibited
CP
Set
acceleration
ACHZ
230
Optional Axis number
Prohibited
CP
Declare arch-motion Z-axis
ADD 103
Optional
Augend
variable Addend
ZR
Add
AEXT 232
Optional
(Position
number) Prohibited
CP
Set
arch-motion composition
AND
119
Optional AND operand variable
Operand
ZR
Logical AND
ARC
187
Optional Passing position number
End position number
PE
Move along arc
ARC2
179
Optional Passing position number
End position number
PE
Move along arc 2
ARCC 184
Optional
Center
position number
Center angle
PE
Move along arc via specification of
center position and center angle
ARCD
183
Optional End position number
Center angle
PE
Move along arc via specification of end
position and center angle
ARCH 240
Optional
Position
number
Position number
PE
Arch motion
ARCS 181
Optional
Passing
position
number
Passing position
number
PE
Move four-dimensionally along arc
ATN 117
Optional
Inverse-tangent assignment
operation
Operand ZR
Inverse
tangent
ATRG
228
Optional Position number
Position number
CP
Set arch trigger
AXST 197
Optional
Variable number
Axis number
CP
Get axis status
B
BASE
157
Optional Reference axis number
Prohibited CP
Set
reference axis
BGPA
218
Optional Palletizing number
Prohibited
CP
Declare start of palletizing setting
BGSR 128
Prohibited
Declaration subroutine
number
Prohibited CP
Start
subroutine
BTPF
118
Optional Output port, flag
Timer setting
CP
Output OFF pulse
BTPN
117
Optional Output port, flag
Timer setting
CP
Output ON pulse
BTXX
116
Optional Start output, flag
(End output, flag)
CP
Output, flag [ON, OF, NT]
C
CANC
160
Optional (Input port to abort)
(CANC type)
CP
Declare port to abort
CHPR
242
Optional 0 or 1
Prohibited
CP
Change task level
CHVL 182
Optional
Axis
pattern
Speed
CP
Change
speed
CIR
186
Optional Passing position 1 number
Passing position 2
number
PE Move
along
circle
CIR2
178
Optional Passing position 1 number
Passing position 2
number
PE
Move along circle 2
CIRS
180
Optional Passing position 1 number
Passing position 2
number
PE
Move three-dimensionally along circle
CLOS
204
Optional Channel number
Prohibited
CP
Close channel
CLR
102
Optional Start-of-clear variable
End-of-clear variable
ZR
Clear variable
COS 106
Optional
Cosine
assignment
variable Operand
ZR
Cosine
CPXX 112
Optional
Comparison
variable Comparison
value
Compare
D
DCL 153
Optional
Deceleration
Prohibited
CP
Set
deceleration
DEG
156
Optional Division angle
Prohibited
CP
Set division angle
DIS
172
Optional Distance
Prohibited
CP
Set spline division distance
DIV 104
Optional
Dividend
variable Divisor
ZR
Divide
DWXX
191
Optional Comparison variable
Comparison value
CP
Loop [EQ, NE, GT, GE, LT, LE]