IAI America XSEL-KET User Manual

Page 356

Advertising
background image

337

Appendix

INTELLIGENT ACTUATOR


I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

13 Expanded I/O3 error

monitor (I/O4)

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V

I/O power source)
(Main application version 0.55 or later)

3: Monitor (Monitor only errors relating to 24-V I/O

power source)
(Main application version 0.55 or later)

* Some exceptions apply.

14 Number

of

ports

using network-I/F-
card remote input

0

0 ~ 256

Refer to the operation manual for each network I/F
card (CC-Link, DeviceNet, etc.).

15 Number

of

ports

using network-I/F-
card remote output

0

0 ~ 256

Refer to the operation manual for each network I/F
card (CC-Link, DeviceNet, etc.).

16 (For

future

extension

= Change prohibited)

0

0 ~ 256

Multiple of 8

17 (For

future

extension

= Change prohibited)

0

0 ~ 256

Multiple of 8

18~

19

(For extension)

0

20 Input filtering periods

2

1 ~ 9

msec

Input signal is recognized when the status is held for
twice the period set by this parameter.

21 Register

input

filtering periods

2

1 ~ 9

msec

Input signal is recognized when the status is held for
twice the period set by this parameter.

22 Remote-I/O-card

fieldbus ready
timeout value

2000

0 ~ 99999

msec

Timeout check is not performed if “0” is set.

23 Multi-point

DIO

external terminal
block overcurrent

Power-supply error

detection input
specification

0H

0H ~ FFFFFFFFH

Bits 0 to 3:

For future extension.

Bits 4 to 7:

Expansion I/O1 (I/O2) input specification

Bits 8 to 11:

Expansion I/O2 (I/O3) input specification

Bits 12 to 15: Expansion I/O3 (I/O4) input specification

(0: No error detection input
1: Error detection input = IN023 in the

card

2: Error detection input = IN047 in the

card

3: Error detection input = IN023/47 in

the card)


* Set this parameter after confirming the

specification of the multi-point DIO terminal block
unit to be connected.

* The input port used as an error detection input

cannot be used as a general-purpose input port.

* Be sure to specify “0” (No error detection input) if

the main application version is 0.82 or earlier.