IAI America XSEL-KET User Manual

Page 381

Advertising
background image

362

INTELLIGENT ACTUATOR

Appendix



Other Parameters

No. Parameter

name

Default value

(Reference)

Input

range

Unit

Remarks

10 Emergency-stop

recovery type

0

0 ~ 4

0: Abort operations/programs
1: Recovery after reset
2: Operation continued (Only during automatic

operation. * If the PC software version is 1.0.0.5
or later or TP application version is 1.01 or later,
operation commands from the PC software/TP
will be aborted on the PC software/TP side.)

3: Abort operations/programs (Software reset when

the emergency stop is reset. The home-return
completion status of incremental-encoder axes
will be reset (EG approximation swap). Main
application version 0.17 or later)

4: Abort operations/programs (Error reset (only with

an error of operation-cancellation level or lower)
and auto-start program start (only if AUTO mode
AND I/O parameter No. 33 = 1 AND I/O
parameter No. 44

 1 AND all-operation-

cancellation factor is not present) when the
emergency stop is reset). There must be a
minimum interval of 1 second after an
emergency stop is actuated before it is reset.
The home-return completion status of
incremental-encoder axes will be retained. Main
application version 0.17 or later.)

11 Safety-gate

open

recovery type

0

0 ~ 2

0: Abort operations/programs
1: Recovery after reset
2: Operation continued (Only during automatic

operation)

* If the PC software version is 1.0.0.5 or later or TP

application version is 1.01 or later, operation
commands from the PC software/TP will be
aborted on the PC software/TP side.

12 Automatic

operation

recognition type

0

0 ~ 3

0: Program is running AND all-operation-

cancellation factor is not present

1: [Program is running OR in AUTO mode] AND all-

operation-cancellation factor is not present

13~

19

(For extension)

0

20 System-memory

backup battery
installation function
type

2

0 ~ 2

0: Not installed (SEL global data/error lists cannot

be recovered from the flash ROM)

1: Not installed (SEL global data/error lists can be

recovered from the flash ROM)

2: Installed

* When the power is turned on without battery

installed, position data can be copied from the
flash ROM.

* Use of setting “1” will be prohibited for the time

being due to limitations.

* When position data is lost due to a battery

error, the position data valid before the flash
ROM was written can be restored

 Input “0”

(not installed) and transfer the setting to the
controller, and then perform a software reset
without writing the flash ROM. The point data
last written to the flash ROM will be restored.
Thereafter, reset this parameter to the original
value. (No remedy is available for recovery of
SEL global data/error lists.)

Advertising
This manual is related to the following products: