4) Internal Circuit Selector Terminals

Silkscreen printed

name

TP (ANSI/IAI) SELECT

Description

This connector terminal block is used to select internal circuits of
the relay box.
The shorting connections between the connector terminals are
changed in accordance with the teaching pendant used.

Connector

MC1.5/6-ST-3.5 (Phoenix Contact)

Terminal Numbers and Descriptions of Internal Circuit Selector Terminals

Terminal number

Description

1

Shorted to pin 2 when the ANSI-compatible teaching pendant SEL-
TD and IA-T-XA are used.
(Opened when the teaching pendant SEL-T and IA-T-XD are
used.)

2

Shorted to pin 1 when the ANSI-compatible teaching pendant SEL-
TD and IA-T-XA are used.
(Opened when the teaching pendant SEL-T and IA-T-XD are
used.)

3

Shorted to pin 4 when the teaching pendant SEL-T and IA-T-XD
are used.
(Opened when the ANSI-compatible teaching pendant SEL-TD is
used.)

4

Shorted to pin 3 when the teaching pendant SEL-T and IA-T-XD
are used.
(Opened when the ANSI-compatible teaching pendant SEL-TD
and IA-T-XA are used.)

5

Shorted to pin 6 when the teaching pendant SEL-T and IA-T-XD
are used.
(Opened when the ANSI-compatible teaching pendant SEL-TD
and IA-T-XA are used.)

6

Shorted to pin 5 when the teaching pendant SEL-T and IA-T-XD
are used.
(Opened when the ANSI-compatible teaching pendant SEL-TD
and IA-T-XA are used.)


















6 1

6 1

When the teaching pendant

SEL-T and IA-T-XD are

used

When the ANSI-compatible teaching

pendant SEL-TD and IA-T-XA are

used

When this wiring pattern is
used, use a dummy plug
for IAI’s teaching pendant.

When this wiring pattern is
used, use a dummy plug
for ANSI-compliant
teaching pendant.