(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
C0C
DW/IF/IS/SL pair-end mismatch error
The branching command syntax is invalid. Correspondence with the last
appearing branching command is invalid when EDIF, EDDO or EDSL is used.
Check the correspondence between IF/IS command and EDIF, DO command
and EDDO or SLCT command and EDSL.
C0D
DW/IF/IS/SL no pair-end error
EDIF, EDDO or EDSL is not found. Check the correspondence between IF/IS
command and EDIF, DO command and EDDO or SLCT command and EDSL.
C0E
BGSR no pair-end error
There is no EDSR for BGSR, or no BGSR for EDSR. Check the correspondence
between BGSR and EDSR.
C0F
DO/IF/IS over-nesting error
The number of nests in a DO or IF/IS command exceeds the limit value. Check
for excessive nesting or branching out of or into the syntax using a GOTO
command.
C10
SLCT over-nesting error
The number of nests in a SLCT command exceeds the limit value. Check for
excessive nesting or branching out of or into the syntax using a GOTO
command.
C11
Subroutine over-nesting error
The number of nests in a subroutine exceeds the limit value. Check for
excessive nesting or branching out of or into the syntax using a GOTO
command.
C12
DO/IF/IS under-nesting error
The EDIF or EDDO position is invalid. Check the correspondence between IF/IS
command and EDIF or DO command and EDDO, or branching out of or into the
syntax using a GOTO command.
C13
SLCT under-nesting error
The EDSL position is invalid. Check the correspondence between SLCT and
EDSR, or branching out of or into the syntax using a GOTO command.
C14
Subroutine under-nesting error
The EDSR position is invalid. Check the correspondence between BGSR and
EDSR, or branching out of or into the syntax using a GOTO command.
C15
SLCT next-step command code error
The program step next to SLCT must be WHEQ, WHNE, WHGT, WHGE,
WHLT, WHLE, WSEQ, WSNE, OTHE or EDSL.
C16
Create stack failed
Initialization of the input-condition-status storage stuck has failed.
C17
Extension-condition code error
Input program step error. The extension condition code is invalid.
C18
Extension-condition LD simultaneous processing over error
The number of LDs processed simultaneously exceeds the limit value.
C19
Extension-condition LD shortage error 1
There is not enough LD when extension condition A or O is used.
C1A
Extension-condition LD shortage error 2
There is not enough LD when extension condition AB or OB is used.
C1C
Unused-LD detection error
An attempt was made to execute a command based on multiple LD condition
that has been saved, without using it in extension condition AB or OB.
C1F
Input-condition CND shortage error
The necessary input condition is not found when an extension condition is used.
C21
Input-condition use error with input-condition prohibited command
Input-condition prohibited commands prohibit the use of input conditions.
C22
Invalid command position error with input-condition prohibited
command
A command for which input condition is prohibited cannot be included in an input
condition nest.
C23
Invalid operand error
Program step error. The necessary operand data is invalid.