(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

C24

Operand type error

Program step error. The operand data type is invalid.

C25

Actuator control declaration error

The setting of actuator control declaration command is invalid.

C26

Timer setting-range over error

The timer setting is invalid.

C27

Timeout setting-range over error during wait

The timeout setting is invalid.

C28

Tick count setting-range error

The Tick count setting is invalid.

C29

DIV command divisor 0 error

“0” was specified as the divisor in the DIV command.

C2A

SQR command range error

The operand value in the SQR command is invalid. Input a value larger
than “0” as data in a SQR command.

C2B

BCD display digit range error

The specified number of BCD display digits is invalid. Specify a value
between 1 and 8.

C2C

Program number error

A program number other than 1 to 64 was specified.

C2D

Step number error

The step number is invalid.

C2E

Blank step shortage error

There are not enough blank steps to save step data. Provide enough
blank steps needed to save step data.

C2F

Axis number error

The axis number is invalid.

C30

Axis pattern error

The axis pattern is invalid.

C32

Operating-axis addition error during command execution

An operating axis for point data was added during continuous point
movement or push-motion movement calculation.

C33

Base axis number error

The base axis number is invalid.

C34

Zone number error

The zone number is invalid.

C35

Point number error

The point number is invalid.

C36

I/O port/flag number error

The I/O port/flag number is invalid.

C37

Flag number error

The flag number is invalid.

C38

Tag number error

The tag number is invalid.

C39

Subroutine number error

The subroutine number is invalid.

C3A

User-opened communication channel number error

The user-opened communication channel number is invalid.

C3B

Parameter number error

The parameter number is invalid.

C3C

Variable number error

The variable number is invalid.

C3D

String number error

The string number is invalid.

C3E

String-variable data count specification error

The specified number of string variables exceeds the area, etc.

C40

String-variable delimiter non-detection error

Delimiter cannot be detected in the string variable.

C41

String-variable copy size over error

The copy size of string variable is too large.

C42

Character count non-detection error during string processing

The character-string length is not defined in string processing. Execute
a string processing command after defining the length with a SLEN
command.