No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

46 Output function selection

300

2

0 ~ 20

0: General-purpose output
1: Output error of operation-cancellation level or

higher (ON)

2: Output error of operation-cancellation level or

higher (OFF)

3: Output error of operation-cancellation level or

higher + emergency stop (ON)

4: Output error of operation-cancellation level or

higher + emergency stop (OFF)

47 Output function selection

301

3

0 ~ 20

0: General-purpose output
1: READY output (PIO trigger program can be

run)

2: READY output (PIO trigger program can be

run and error of operation-cancellation level or
higher is not present) (Main application version
0.20 or later)

3: READY output (PIO trigger program can be

run and error of cold-start level or higher is not
present) (Main application version 0.20 or
later)

48 Output function selection

302

2

0 ~ 20

0: General-purpose output
1: Emergency-stop output (ON)
2: Emergency-stop output (OFF)

49 Output function selection

303

0

0 ~ 5

0: General-purpose output
1: AUTO mode output
2: Output during automatic operation (Other

parameter No. 12)

50 Output function selection

304

0

0 ~ 5

0: General-purpose output

1: Output if all valid axes are at home (= 0)

2: Output if all valid axes completed home return

(coordinates confirmed)

3: Output if all valid axes are at preset home

coordinates (Main application version 0.21 or

later)

* To move an absolute-encoder axis to

coordinates 0 or the preset home coordinates,

use a MOVP command instead of a HOME

command.

51 Output function selection

305

0

0 ~ 5

0: General-purpose output

1: For future extension

2: Output when axis-1 servo is ON (system-

monitored task output)

(Main application version 0.44 or later)

3: For future extension.

4: Brake unlock output (Main application version

0.97 or later/F-ROM 16-Mbit version only)

52 Output function selection

306

0

0 ~ 5

0: General-purpose output

1: For future extension

2: Output when axis-2 servo is ON (system-

monitored task output)

(Main application version 0.44 or later)

3: For future extension.

4: Brake unlock output (Main application version

0.97 or later/F-ROM 16-Mbit version only)

53 Output function selection

307

0

0 ~ 5

0: General-purpose output

1: For future extension

2: Output when axis-3 servo is ON (system-

monitored task output)

(Main application version 0.44 or later)

3: For future extension.

4: Brake unlock output (Main application version

0.97 or later/F-ROM 16-Mbit version only)