IAI America XSEL-KET User Manual

Page 357

Advertising
background image

338

INTELLIGENT ACTUATOR

Appendix


I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

24 I/O setting bit pattern 1

2

0H ~ FFFFFFFFH

Bits 0 to 3:
RDY OUT function selection (System IO)
(0: SYSRDY (Software = PIO trigger program can
be run) and hardware is normal (emergency stop
has not be actuated and hardware error is not
present)
1: Error of operation-cancellation level or higher

is not present

* This setting can be selected only when the

main CPU board’s hardware versions are
MREV = 0/FREV = c or later.

2: Error of cold-start level or higher is not present
* This setting can be selected only when the

main CPU board’s hardware versions are
MREV = 0/FREV = c or later.)

(Main application version 0.56 or later)

Bits 4 to 7:
RDY LED function selection
(0: Program can be run
1: Error of operation-cancellation level or higher

is not present

2: Error of cold-start level or higher is not

present)

(Main application version 0.56 or later)

25 I/O setting bit pattern 2

0

0H ~ FFFFFFFFH

Bits 0 to 31: For future extension.

26 I/O setting bit pattern 3

0

0H ~ FFFFFFFFH

Bits 0 to 3:
Function selection for uninstalled output port
(0: No operation
1: Internal ON/OFF operation
* An uninstalled output port operates in the

same manner as a normal output port, except
that it does not produce a physical output to
an external device.

* To use an uninstalled output port as a flag,

specify it in the non-operating general-purpose
output area using one of I/O parameter Nos.
70 to 73. Do not specify it using one of various
system function output port numbers.)

(Main application version 0.98 or later)

27

~

29

(For extension)

0

30 Input function selection

000

1

0 ~ 5

0: General-purpose input
1: Program start signal (ON edge) (007 to 013:

BCD-specified program number)

2: Program start signal (ON edge) (007 to 013:

Binary-specified program number)

* If this parameter is used as a program start

signal, turn ON the signal for at least 100
msec so that the program will start without fail.

31 Input function selection

001

0

0 ~ 5

0: General-purpose input
1: Software reset signal (1 second ON)
* If continued operation is specified as the

action upon emergency stop, enable the
software reset signal (to provide a means of
canceling the operation).

32 Input function selection

002

0

0 ~ 5

0: General-purpose input
1: Servo ON
* ON edge: Equivalent to the all-valid-axis servo

ON command, OFF edge: Equivalent to the
all-valid-axis servo OFF command (A
minimum interval of 1.5 seconds is required)
(Must be executed in non-operating condition)