(4) Wiring

1. RS232C

wiring










































Flow control (software flow, hardware flow) is not provided. If the other side does not use flow
control, commercial RS232C cross cables can be used.

Control

circuit

SIO expansion board

Supplied joint cable

CB-ST-232J001

D-sub, 9-pin

D-sub, 9-pin

Or

Provided by the user

SD 1

3

SD 3

3 SD

RD 2

2

RD 2

2 RD

RS 3

7

RS 7

7 RS

CS 4

8

CS 8

8 CS

ER 5

4

ER 4

4 ER

DR 6

6

DR 6

6 DR

SG 7

5

SG 5

5 SG

SD 3

3 SD

RD 2

2 RD

RS 7

7 RS

CS 8

8 CS

ER 4

4 ER

DR 6

6 DR

SG 5

5 SG