Areca 24/4 Internal/External Port Pcie 3.0 12 Gb/s SAS/SATA Raid Controller 2Gb Cache User Manual
12gb/s sas raid cards user manual
Advertising
Table of contents
Document Outline
- 1. Introduction
- 2. Hardware Installation
- 3. McBIOS RAID Manager
- 3.1 Starting the McBIOS RAID Manager
- 3.2 McBIOS RAID manager
- 3.3 Configuring Raid Sets and Volume Sets
- 3.4 Designating Drives as Hot Spares
- 3.5 Using Quick Volume /Raid Setup Configuration
- 3.6 Using Raid Set/Volume Set Function Method
- 3.7 Main Menu
- 3.7.1 Quick Volume/Raid Setup
- 3.7.2 Raid Set Function
- 3.7.3 Volume Set Function
- 3.7.3.1 Create Volume Set (0/1/10/3/5/6)
- • Volume Name
- • Capacity
- • Stripe Size
- • SCSI ID
- • Cache Mode
- • Write Protect
- • Tag Queuing
- 3.7.3.2 Create Raid30/50/60 (Volume Set 30/50/60)
- 3.7.3.3 Delete Volume Set
- 3.7.3.4 Modify Volume Set
- 3.7.3.5 Check Volume Set
- 3.7.3.6 Stop Volume Check
- 3.7.3.7 Display Volume Set Info.
- 3.7.4 Physical Drives
- 3.7.5 Raid System Function
- 3.7.5.1 Mute The Alert Beeper
- 3.7.5.2 Alert Beeper Setting
- 3.7.5.3 Change Password
- 3.7.5.4 JBOD/RAID Function
- 3.7.5.5 Background Task Priority
- 3.7.5.6 SATA NCQ Support
- 3.7.5.7 HDD Read Ahead Cache
- 3.7.5.8 Volume Data Read Ahead
- 3.7.5.9 Hdd Queue Depth Setting
- 3.7.5.10 Empty HDD Slot LED
- 3.7.5.11 Controller Fan Detection
- 3.7.5.12 Auto Activate Raid Set
- 3.7.5.13 Disk Write Cache Mode
- 3.7.5.14 Write Same Support
- 3.7.5.15 Capacity Truncation
- 3.7.6 More System Functions
- 3.7.7 HDD Power Management
- 3.7.8 Ethernet Configuration
- 3.7.9 Alert By Mail Config
- 3.7.10 View System Events
- 3.7.11 Clear Events Buffer
- 3.7.12 Hardware Monitor
- 3.7.13 System Information
- 4. Driver Installation
- 5. ArcHTTP Proxy Server Installation
- 6. Web Browser-based Configuration
- 6.1 Start-up McRAID Storage Manager
- 6.2 McRAID Storage Manager
- 6.3 Main Menu
- 6.4 Quick Function
- 6.6 Volume Set Functions
- 6.7 Security Function
- 6.8 Physical Drive
- 6.9 System Controls
- 6.9.1 System Config
- • System Beeper Setting
- • Background Task Priority
- • JBOD/RAID Configuration
- • SATA NCQ Support
- • HDD Read Ahead Cache
- • Volume Data Read Ahead
- • HDD Queue Depth
- • Empty HDD Slot LED
- • CPU Fan Detection
- • SES2 Support
- • Max Command Length
- • Auto Activate Incomplete Raid
- • Disk Write Cache Mode
- • Write Same For Initialization
- • Hot Plugged Disk For Rebuilding
- • PCIE Gen3
- • SATA MACH.2 Striping
- • SES2 H/W Monitor
- • Disk Capacity Truncation Mode
- • Smart Option For HDD
- • Smart Polling Interval
- 6.9.2 Advanced Configuration
- • TLER Setting
- • Timeout Setting
- • Number of Retries
- • Buffer Threshold
- • Amount of Read Ahead
- • Read Ahead Count
- • Read Ahead Requests
- • Number of AV Stream
- • Optimize AV Recording
- • Read Performance Margin
- • Write Performance Margin
- • Read And Discard Parity Data
- • Fail Disk For Any Timeout
- • Hitachi/WDC/Seagate SATA HDD Speed
- • BIOS Selection
- • PCIE Link Down Reset
- • Active Cable Management
- • Host Command Queue Mode
- • End Device Frame Buffering
- • PCIe Command Queue Depth
- • Write Cache Amount
- • Save SED Key In Controller
- • Dual Path Usage
- • Ext Connector#1 Speed Limit
- • Ext Connector#2 Speed Limit
- • Fail Disk For Reading Error
- 6.9.3 HDD Power Management
- 6.9.4 Ethernet Configuration
- 6.9.5 Alert By Mail Configuration
- 6.9.6 SNMP Configuration
- 6.9.7 NTP Configuration
- 6.9.8 View Events/Mute Beeper
- 6.9.9 Generate Test Event
- 6.9.10 Clear Events Buffer
- 6.9.11 Modify Password
- 6.9.12 Update Firmware
- 6.9.1 System Config
- 6.10 Information
- Appendix A
- Appendix B
- Appendix C
- Appendix D
- Appendix E
- Appendix F
- Appendix G
- Appendix H
- Appendix I