WEB BROWSER-BASED CONFIGURATION

• Ext Connector#1 Speed Limit

This option is only available on the ARC-1883X/1883LP. It is

used to limit the external connector speed in case of compatible

issue on low speed connected enclosure.

• Ext Connector#2 Speed Limit

This option is only available on the ARC-1883X. It is used to

limit the external connector speed in case of compatible issue

on low speed connected enclosure.

• Fail Disk For Reading Error

This option is available to improve the fail disk function if the

disk has too many reading errors. This function is the option

that RAID controller will kill off the HDD for reading error ac-

count setting value.

- 3 errors in 70 seconds: this option also includes 4 errors in

100 seconds, 5 errors in 120 seconds

- 6 errors in 2 minutes

: this option also includes 8 errors in 180

seconds, 10 errors in 240 seconds

- 9 errors in 3 minutes: this option also includes 12 errors in

270 seconds, 15 errors in 360 seconds

- Reading Error Does Not Fail Disk