Appendix e, Event notification configurations, A. device event – Areca 24/4 Internal/External Port Pcie 3.0 12 Gb/s SAS/SATA Raid Controller 2Gb Cache User Manual

Page 231: Appendix

Advertising
background image

231

APPENDIX

Appendix E

Event Notification Configurations

The controller classifies disk array events into four levels depending on

their severity. These include level 1: Urgent, level 2: Serious, level 3:

Warning and level 4: Information. The level 4 covers notification

events such as initialization of the controller and initiation of the re-

building process; Level 2 covers notification events which once have

happen; Level 3 includes events which require the issuance of warning

messages; Level 1 is the highest level, and covers events that need

immediate attention (and action) from the administrator. The following

lists sample events for each level:

Event

Level

Meaning

Action

Device Inserted

Warning

HDD inserted

Device Removed Warning

HDD removed

Reading Error

Warning

HDD reading error

Keep Watching HDD status, may be

it caused by noise or HDD unstable.

Writing Error

Warning

HDD writing error

Keep Watching HDD status, may be

it caused by noise or HDD unstable.

ATA Ecc Error

Warning

HDD ECC error

Keep Watching HDD status, may be

it caused by noise or HDD unstable.

Change ATA Mode Warning

HDD change ATA

mode

Check HDD connection

Time Out Error

Warning

HDD time out

Keep Watching HDD status, may be

it caused by noise or HDD unstable.

Device Failed

Urgent

HDD failure

Replace HDD

PCI Parity Error

Serious

PCI parity error

If only happen once, it may be

caused by noise. If always happen,

please check power supply or

contact to us.

Device

Failed(SMART)

Urgent

HDD SMART failure

Replace HDD

PassThrough Disk

Created

Inform

Pass Through Disk

created

PassThrough Disk

Modified

Inform

Pass Through Disk

modified

PassThrough Disk

Deleted

Inform

Pass Through Disk

deleted

A. Device Event

Advertising