Bios configuration – Areca 24/4 Internal/External Port Pcie 3.0 12 Gb/s SAS/SATA Raid Controller 2Gb Cache User Manual

Page 77

Advertising
background image

BIOS CONFIGURATION

77

Note:

Power failure may damage the migration data. Please

backup the RAID data before you start the migration func-

tion.

To expand an existing volume noticed:

Only the last volume can expand capacity.

When expand volume capacity, you can’t modify stripe size or

modify RAID revel simultaneously.

You can expand volume capacity, but can’t reduce volume

capacity size.

After volume expansion, the volume capacity can not be

decreased.

For greater 2TB expansion:

If your system installed in the volume, don't expand the

volume capacity greater 2TB, currently OS can’t support boot

up from a greater 2TB capacity device.

Expand over 2TB used 64bit LBA mode. Please make sure

your OS supports 64bit LBA before expand it.

3.7.3.4.2 Volume Set Migration

Migrating occurs when a volume set is migrating from one RAID

level to another, when a volume set strip size changes, or when

a disk is added to a RAID set. Migration state is displayed in the

volume state area of the “Volume Set Information” screen.