BIOS CONFIGURATION

89

3.7.5.8 Volume Data Read Ahead

The volume read data ahead parameter specifies the controller

firmware algorithms which process the read ahead data blocks

from the disk. The "Data Read Ahead" parameter is normal by

default. To modify the value, you must set it from the "Raid

System Function" using the 'Volume Data Read Ahead" option.

The default "Normal" option satisfies the performance require-

ments for a typical volume. The "Disabled" value implies no read

ahead. The most efficient value for the controllers depends on

your application. The "Aggressive" value is optimal for sequential

access but it degrades random access.

I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System

Areca Technology Corporation RAID Controller

Main Menu

Quick Volume/Raid Setup

Raid Set Function

Volume Set Function

Physical Drives

Raid System Function

More System Functions

Hdd Power Management

Ethernet Configuration

Alert By Mail Config

View System Events

Clear Event Buffer

Hardware Monitor

System information

Raid System Function

Raid System Function

Mute The Alert Beeper

Alert Beeper Setting

Change Password

JBOD/RAID Function

Background Task Priority

SATA NCQ Support

HDD Read Ahead Cache

Volume Data Read Ahead

Hdd Queue Depth Setting

Empty HDD Slot LED

Controller Fan Detection

Auto Activate Raid Set

Disk Write Cache Mode

Write Same Support

Capacity Truncation

Volume Data Read Ahead

Volume Data Read Ahead

Enabled

Aggressive

Conservative

Disabled

Normal

3.7.5.9 Hdd Queue Depth Setting

This parameter is adjusted the queue depth capacity of NCQ

(SAS HDD) or Tagged Command Queuing (SAS HDD) which

transmits multiple commands to a single target without waiting

for the initial command to complete.

Advertising