Amount of read ahead, Read ahead count, Read ahead requests – Areca 24/4 Internal/External Port Pcie 3.0 12 Gb/s SAS/SATA Raid Controller 2Gb Cache User Manual

Page 188: Number of av stream, Web browser-based configuration

Advertising
background image

WEB BROWSER-BASED CONFIGURATION

188

quently, this can prevent a pause in data flow and there will

be continues data access and stream. This feature is very use

ful for the video streaming applications where there is high

demand for constant non-stop data flow with no interruption

due to lower performance of specific hardware.

• Amount of Read Ahead

Read-Ahead data is buffered in the RAID controller cache,

however, thereby cutting down on the amount of I/O traffic to

the disk. The Amount of Read Ahead defines how many data of

reading at a time, making more efficient use of the RAID sub

system. This makes it possible to locate and re-issue the data

without repetitive hard parsing activities. The Amount of Read

Ahead parameter is used to allocate an amount of memory in

the cache memory the frequently executed queries and return

the result set back to the host without real disk read execution.

Default value is Auto: Controller will base on the HDD number

to set the amount of Read Ahead value. You can select between

512KB ~ 16MB.

• Read Ahead Count

The Read Ahead count is used to define how many times (1, 2,

3, ….., 10) of the “Amount of Read Ahead X Read Ahead Re-

quests“ data reading at a time. Default value is Auto: Controller

will base on the HDD number to set the amount of Read Ahead

Count value. You can select between Auto, 1, 2, ….. or 10.

• Read Ahead Requests

The Read Ahead Requests is used to define how many times (1,

2, 3) of the “Amount of Read Ahead “ data reading at a time.

Default value is 1. You can select between 1, 2, or 3.

• Number of AV Stream

RAID controllers are required to have not only the function of

processing ordinary data but also the function of dealing with

AV (audio/video) stream data needing real-time processing.

Since the bus cycle used in RAID controller was designed to

transfer the computer data exactly, it was unsuitable for the

transfer of AV stream needing great band widths. They are

required to do some setting for the handshaking during the

processing of stream data. This setting is an object of transfer-

ring stream data efficiently on an existing RAID controller.

Advertising