5. Modbus RTU

97

Modbus

5.3.15 Current Speed Reading <<VNOW>>

(1) Function

The monitored data of actual motor speed is read. The speed may be positive or negative

depending on the moving direction of the actuator.

The unit is 0.01 mm/sec.

(2) Query format

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Start address [H]

2

900A

Current speed monitor

Number of registers [H]

2

0002

Reading addresses 900A

H

to

900B

H

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

8

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Number of data bytes [H]

1

04

Reading 2 registers = 4 bytes

Data [H]

4

Current speed

Current speed [Hex]

Indicated in units of 0.01

mm/sec.

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

9