5. Modbus RTU

153

Modbus

(3) Query format

1 register = 2 bytes = 16-bit data

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

00

H

if broadcast is specified

Function code [H]

1

10

Numerical value specification

Start address [H]

2

Arbitrary

Refer to 5.6.1 (2), “Start

address list”

Number of registers [H]

2

Arbitrary

Refer to 5.6.1 (2), “Start

address list”

Number of bytes [H]

1

In accordance with

the number of

registers above

Enter the value twice as large

as the number of registers

specified above

Changed data 1 [H]

2

Refer to 5.6.1 (2), “Start

address list ”

Changed data 2 [H]

2

Refer to 5.6.1 (2), “Start

address list”

Changed data 3 [H]

2

Refer to 5.6.1 (2), “Start

address list”

:

:

:

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

Up to 256

(4) Response format

When normally changed, the response message responds with a copy of the query message

excluding the number of bytes and changed data.

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

00

H

if broadcast is specified

Function code [H]

1

10

Numerical value specification

Start address [H]

2

Arbitrary

Refer to 5.6.1 (2), “Start

address list”

Number of registers [H]

2

Arbitrary

Refer to 5.6.1 (2), “Start

address list”

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

Up to 8