6. Modbus

ASCII

256

Modbus

6.5.10 Teaching Mode Command <<MOD>>

(1) Function

This bit switches between the normal operation mode and teaching mode.

(2) Query format

Field

Number of

characters

ASCII mode

character string

(fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1 (01

H

to 10

H

)

00

H

when broadcast is specified

Function code [H]

2

‘0’, ‘5’

Write to a single coil DO.

Start address [H]

4

‘0’, ‘4’ ‘1’, ‘4’

Switch between the normal mode and

the teaching mode.

Changed data [H]

4

Arbitrary

Teaching mode: ‘F’, ‘F’, ‘0’, ‘0’

Normal operation mode: ‘0’, ‘0’, ‘0’, ‘0’

Error check [H]

2

LRC calculation

result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

17

(3) Response

If the change is successful, the response message will be the same as the query.

If invalid data is sent, an exception response (refer to section 7) will be returned, or no response will

be returned.