Modbus – IAI America ROBO Cylinder Series User Manual

Page 107

Advertising
background image

5. Modbus RTU

99

Modbus

5.3.16 Current Ampere Reading <<CNOW>>

(1) Function

This bit reads the monitor data of the motor current (torque current command value), indicated in

units of mA.

(2) Query format

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Start address [H]

2

900C

Current ampere monitor

Number of registers [H]

2

0002

Reading addresses 900C

H

to

900D

H

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

8

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Number of data bytes [H]

1

04

Reading 2 register = 4 bytes

Data [H]

4

Motor current monitor Motor current monitor [Hex]

The unit is mA.

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

9