Modbus – IAI America ROBO Cylinder Series User Manual

Page 140

Advertising
background image

5. Modbus RTU

132

Modbus

5.4.10 Teaching Mode Command <<MOD>>

(1) Function

This bit switches between the normal operation mode and teaching mode.

(2) Query format

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

00

H

when broadcast is

specified

Function code [H]

1

05

Write to a single coil DO.

Start address [H]

2

0414

Switch between the normal

mode and the teaching mode.

Changed data [H]

2

Arbitrary

Teaching mode: FF00

H

Normal operation mode: 0000

H

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

8

(3) Response

If the change is successful, the response message will be the same as the query.

If invalid data is sent, an exception response (refer to section 7) will be returned, or no response

will be returned.