6. Modbus

ASCII

209

Modbus

6.4.10 I/O Port Output Signal Status Reading <<DOPM>>

(1) Function

Port output values of the RC controller are stored directly regardless of the PIO pattern.

(2) Query format

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Start address [H]

4

‘9’, ‘0’, ‘0’, ‘4’

Output port monitor register

Number of registers [H]

4

‘0’, ‘0’, ‘0’, ‘1’

Reading address 9004

H

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

17

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Number of data bytes [H]

2

‘0’, ‘2’

Reading 1 register

= 2 bytes

Data 1 [H]

4

DO output value

DI output value [Hex]

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

15