5. Modbus RTU

61

Modbus

FC

Function

Symbol

Function Summary

Combination

with PIO

Broad-

cast Page

03 Zone output signal

read

ZONS

This function reads the following 6 statuses:

[1] LS2 (PIO pattern solenoid valve mode

[3-point type]

[2] LS1 (PIO pattern solenoid valve mode

[3-point type]

[3] LS0 (PIO pattern solenoid valve mode

[3-point type]

[4] Position zone

[5] Zone 2

[6] Zone 1

{

106

03

Positioning

completed position

number read

POSS

This function reads the following 9 statuses:

[1] Position complete number bit 256

[2] Position complete number bit 128

[3] Position complete number bit 64

[4] Position complete number bit 32

[5] Position complete number bit 16

[6] Position complete number bit 8

[7] Position complete number bit 4

[8] Position complete number bit 2

[9] Position complete number bit 1

{

108

03 Controller status

signal read 5

SSSE

This function reads the following 2 statuses:

[1] Cold start level alarm occurred/not

occurred

[2] RTC (calendar) function used/not used

(ERC3, PCON-CA/CFA type only)

{

110

03 Force feedback data

write

FBFC The current measurement on the load cell is

read in units of 0.01 N.

{

112

05

Safety speed

enable/disable

switching

SFTY This function issues a command to

enable/disable the safety speed.

{

116

05 Servo ON/OFF

SON This function issues a command to turn the

servo ON/OFF.

{

118

05 Alarm reset

ALRS This function issues a command to reset

alarms/cancel the remaining travel.

{

120

05 Forced brake

release

BKRL This function issues a command to forcibly

release the brake.

{

122

05 Pause

STP This function issues a pause command.

{

124

05 Home return

HOME This function issues a home return operation

command.

{

126

05 Positioning

operation start

CSTR This signal starts a position number

specified movement.

{

128

05 Jog/inch switching

JISL This function switches between the jogging

mode and the inching mode

{

130

05 Teaching mode

command

MOD This function switches between the normal

mode and the teaching mode

{

132

05 Position data load

command

TEAC This function issues a current position load

command in the teaching mode.

{

134

05 Jog+ command

JOG+ This function issues a jogging/inching

command in the direction opposite home.

{

136

05 Jog- command

JOG- This function issues a jogging/inching

command in the direction of home.

{

138