Modbus – IAI America ROBO Cylinder Series User Manual

Page 211

Advertising
background image

6. Modbus

ASCII

203

Modbus

6.4.8 Present Alarm Code Query <<ALMC>>

(1) Function

Whether the controller is normal or any alarm presently detected is indicated by a code.

If no alarm is present, 00

H

is stored.

[For details on alarm codes, refer to the operation manual that comes with each controller.]

(2) Query format

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Start address [H]

4

‘9’, ‘0’, ‘0’, ‘2’

Present alarm codes

Number of registers [H]

4

‘0’, ‘0’, ‘0’, ‘1’

Reading address 9002

H

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

17

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Number of data bytes [H]

2

‘0’, ‘2’

Reading 1 register

= 2 bytes

Data 1 [H]

4

Alarm code

Alarm code [Hex]

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

15