6. Modbus

ASCII

289

Modbus

(Example 5)

Change the speed from 100 mm/s to 50 mm/s while the actuator is moving.

Pitch

[mm]

Positioning

band

[mm]

Speed

[mm/s]

Acceleration/

deceleration

[G]

Push

[%]

Control flag

10

0.1

100 o 50

0.3

0

Incremental

(bit3 = 1)

(1) Start moving at a speed of 100 mm/s. [Refer to Example [4], “Moving in the incremental (pitch

feed) mode” above.]

„

Query : 01 10 9900 0009 12 0000 03E8 0000 000A 0000 2710 001E 0000 0008 E9[CR][LF]

„

Response : 01 10 9900 0009 4D[CR][LF]

(2) Change the speed to 50 mm/s.

„

Query : 01 10 9904 0005 0A 0000 1388 001E 0000 0008 82[CR][LF]

„

Response: 01 10 9904 0005 4D[CR][LF]

--- The query message is copied, except for the number of bytes and new data, and returned

as a response.

„ᴾ

Breakdown of Query Message (Change the speed to 50 mm/s. [Refer to the above example for the

query message used to start the movement at 100 mm/s.])

Field

ASCII mode

fixed character

string

Converted

ASCII code

data [H]

Remarks

Header

‘:’

3A

Slave address

‘0’, ‘1’

3031

Axis No. 0 + 1

Function code

‘1’, ‘0’

3130

Start address

‘9’, ‘9’, ‘0’, ‘4’

39393034

The start address is the target position

specification register 9904

H

.

Number of registers

‘0’, ‘0’, ‘0’, ‘5’

30303032

Specify 9904

H

through 9908

H

as the

addresses to be written.

Number of bytes

‘0’, ‘A’

3034

5 (registers) x 2 = 10(bytes) o A

H

‘0’, ‘0’, ‘0’, ‘0’

30303030

All upper bits of the 32-bit data are 0.

Changed data 1, 2

(target position)

Input unit (0.01 mm)

‘1’, ‘3’, ‘8’, ‘8’

31333838

50 [mm/s] × 100 = 5000

ĺ 1388

H

Changed data 7

(acceleration/deceleration)

Input unit (0.01 G)

‘0’, ‘0’, ‘1’, ‘E’

30303145

0.3 [G] × 100 = 30 ĺ 001E

H

Changed data 8 (push)

Input unit (%)

‘0’, ‘0’, ‘0’, ‘0’

30303030

0 [%] ĺ 0

H

Changed data 9 (control

flag)

‘0’, ‘0’, ‘0’, ‘8’

30303038

(Incremental setting)

1000b o 0008

H

Error check

‘8’, ‘2’

3832

LRC check calculation result o 82

H

Trailer

‘CR’, ‘LF’

0D0A

Total number of bytes

39