5. Modbus RTU

171

Modbus

(3) Query format

1 register = 2 bytes = 16-bit data

Field

Number of

data items

(Number of

bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

00

H

when broadcast is specified

Function code [H]

1

10

Numerical value command

Start address [H]

2

Arbitrary

Refer to 5.6.2 (2), “Start address list.”

Number of registers [H]

2

Arbitrary

Refer to 5.6.2 (2), “Start address list.”

Number of bytes [H]

1

In accordance

with the above

registers

A value corresponding to twice the number

of registers specified above is input.

Changed data 1 [H]

2

Refer to “5.6.2 (2) Start address list.”

Changed data 2 [H]

2

Refer to “5.6.2 (2) Start address list.”

Changed data 3 [H]

2

Refer to “5.6.2 (2) Start address list.”

:

:

:

Error check [H]

CRC (16 bits)

End

None

Silent interval

Total number of bytes

Up to 256

(4) Response format

If the change is successful, a response message that is effectively a copy of the query message,

except for the byte count and new data, will be returned.

Field

Number of

data items

(Number of

bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent mode

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

00

H

when broadcast is specified

Function code [H]

1

10

Numerical value command

Start address [H]

2

Arbitrary

Refer to 5.6.2 (2), “Start address list.”

Number of registers [H]

2

Arbitrary

Refer to 5.6.2 (2), “Start address list.”

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

Up to 8