5. Modbus RTU

130

Modbus

5.4.9 Jog/Inch Switching <<JISL>>

(1) Function

This bit switches between jogging and inching.

If this bit switches while the actuator is jogging, the actuator will decelerate to a stop.

If this bit switches while the actuator is inching, the inching movement will continue.

(2) Query format

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

00

H

when broadcast is

specified

Function code [H]

1

05

Write to a single coil DO.

Start address [H]

2

0411

Jog/inch switching

Changed data [H]

2

Arbitrary

Inching operation status:

FF00

H

Jogging operation status:

0000

H

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

8

(3) Response

If the change is successful, the response message will be the same as the query.

If invalid data is sent, an exception response (refer to section 7) will be returned, or no response

will be returned.