Modbus – IAI America ROBO Cylinder Series User Manual

Page 41

Advertising
background image

4. Communication

33

Modbus

(1) Data of alarm detail code (Address = 0500

H

) (ALA0)

Bitᴾ

Symbolᴾ

Nameᴾ

Functionᴾ

15

-

Alarm detail code 32768

14

-

Alarm detail code 16384

13

-

Alarm detail code 8192

12

-

Alarm detail code 4096

11

-

Alarm detail code 2048

10

-

Alarm detail code 1024

9

-

Alarm detail code 512

8

-

Alarm detail code 256

7

-

Alarm detail code 128

6

-

Alarm detail code 64

5

-

Alarm detail code 32

4

-

Alarm detail code 16

3

-

Alarm detail code 8

2

-

Alarm detail code 4

1

-

Alarm detail code 2

0

-

Alarm detail code 1

It shows the alarm detail code numbers.ᴾ

It is output when an alarm is issued that possesses an

alarm detail code. It shows 0

H

when either there is no

alarm generated or an alarm is generated but it

possesses no alarm detail code.ᴾ

Alarm detail codes are read out in binary codes.ᴾ

Check in the operation manual for the controller for the

content of an alarm detail code as well as an alarm code.ᴾ

(2) Data of alarm address (Address = 0501

H

) (ALA0)

Bit

Symbol

Name

Functionᴾ

15

-

Alarm address 32768

14

-

Alarm address 16384

13

-

Alarm address 8192

12

-

Alarm address 4096

11

-

Alarm address 2048

10

-

Alarm address 1024

9

-

Alarm address 512

8

-

Alarm address 256

7

-

Alarm address 128

6

-

Alarm address 64

5

-

Alarm address 32

4

-

Alarm address 16

3

-

Alarm address 8

2

-

Alarm address 4

1

-

Alarm address 2

0

-

Alarm address 1

It shows the alarm address.ᴾ

The stored virtual address is output when a value stored

in the virtual domain is the cause of the generated alarm.

It shows FFFF

H

when either there is no alarm generated

or an alarm is generated but the virtual domain is not the

cause of it.ᴾ

Alarm address are read out in binary codes.ᴾ