Modbus – IAI America ROBO Cylinder Series User Manual

Page 39

Advertising
background image

4. Communication

31

Modbus

4.3.2 Details of Modbus Registers

Reference page

Address

[hex]

Area name

Description

Symbol

RTU

ASCII

0000 to 04FF Reserved for

system

0500

Alarm detail code

ALA0

30

30

0501

Alarm address

ALA0

30

30

0502

Always 0

-

-

-

0503

Alarm code

ALC0

31

31

0504

Detailed

information of

the alarm

detected lately

Alarm occurrence time

ALT0

64

32

192

32

0506 to 0CFF Reserved for

system

0D00

Device control register 1

DRG1

33

33

0D01

Device control register 2

DRG2

34

34

0D03

I/O control

information

category

Position number specification register

POSR

149

35

276

35

0D04 to 0FFF Reserved for

system

1000 to 3FFF

Offset [hex]

+0000

H

Target position

PCMD

+0002

H

Positioning band

INP

+0004

H

Speed command

VCMD

+0006

H

Individual zone boundary +

ZNMP

+0008

H

Individual zone boundary -

ZNLP

+000A

H

Acceleration command

ACMD

173

300

+000B

H

Deceleration command

DCMD

+000C

H

Push-current limiting value

PPOW

+000D

H

Load current threshold

LPOW

Position table

information

(low-speed

memory area)

+000E

H

Control flag specification

CTLF

171

174

298

301

* Detailed

addresses

can be

calculated

using the

formula to the

right. o

* Address = 1000

H

+ (16 x position No.) + offset

4000 to 83FF Reserved for

system

8400

Total moving count

(Note 1)

TLMC

36

66

36

194

8402

Total moving distance

(Note 1)

ODOM

37

68

37

196

841A

Current time(dedicated for SCON-CA)

TIMN

38

70

38

198

8420

Current time(dedicated for PCON-CA/CFA)

TIMN

38

70

38

198

842E

Maintenance

information

(dedicated for

models

applicable to

calendar function)

Total FAN driving time(dedicated for PCON-

CFA)

TFAN

39

74

39

202

8430 to 8FFF Reserved for

system

9000

Current position register

PNOW

76

204

9002

Present alarm code register

ALMC

78

206

9003

Input port register

DIPM

80

208

9004

Output port register

DOPM

(61)

84

(189)

212

9005

Device status 1 register

DSS1

40(61) 88 40(189) 216

9006

Device status 2 register

DSS2

41(61) 90 41(189) 218

9007

Expansion device status register

DSSE

42(61) 92 42(189) 220

9008

System status register

STAT

43(61) 94 43(189) 222

900A

Current speed monitor register

VNOW

96

224

900C

Current ampere monitor register

CNOW

98

226

900E

Deviation monitor register

DEVI

100

228

9010

System timer register

STIM

(61)

102

(189)

230

9012

Special input port register

SIPM

44(61) 104 44(189) 232

9013

Zone status register

ZONS

45(61) 106 45(189) 234

9014

Position complete number status register

POSS

46(61) 108 46(189) 236

9015

Controller

monitor

information

category

Expansion System status register

SSSE

47(61) 110 47(189) 238

9016 to 901D Reserved for

system

Note 1 Dedicated for PCON-CA/CFA, SCON-CA and ERC3