5. Modbus RTU

165

Modbus

(Example 5)

Change the speed from 100 mm/s to 50 mm/s while the actuator is moving.

Pitch

[mm]

Positioning

band

[mm]

Speed

[mm/s]

Acceleration/

deceleration

[G]

Push

[%]

Control flag

10

0.1

100 o 50

0.3

0

Incremental

(bit3 = 1)

(1) Start moving at a speed of 100 mm/s. [Refer to Example [4], “Moving in the incremental

(pitch feed) mode” above.]

„

Query : 01 10 9900 0009 12 0000 03E8 0000 000A 0000 2710 001E 0000 0008 F3A0

„

Response : 01 10 9900 0009 2E93

(2) Change the speed to 50 mm/s.

„

Query : 01 10 9904 0005 0A 0000 1388 001E 0000 0008 BD83

„

Response: 01 10 9904 0005 6F57

--- The query message is copied, except for the number of bytes and new data, and returned

as a response.

„ᴾ

Breakdown of Query Message (Change the speed to 50 mm/s. [Refer to the above example for the

query message used to start the movement at 100 mm/s.])

Field

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address

01

H

Axis No. 0 + 1

Function code

10

H

Start address

9904

H

The start address is the target position specification

register 9904

H

.

Number of registers

0005

H

Specify 9904

H

through 9908

H

as the addresses to be

written.

Number of bytes

0A

H

5 (registers) x 2 = 10 (bytes) o A

H

0000

H

All upper bits of the 32-bit data are 0.

New data 5, 6 (speed)

Input unit (0.01 mm/s)

1388

H

50 [mm/s] × 100 = 5000 o 1388

H

New data 7

(acceleration/deceleration)

Input unit (0.01 G)

001E

H

0.3 [G] × 100 = 30 o 001E

H

New data 8 (push)

Input unit (%)

0000

H

0 [%]o 0

H

New data 9 (control flag)

0008

H

(Incremental setting)

1000bĺ0008

H

Error check

BD83

H

CRC check calculation result o BD83

H

End

None

Silent interval

Total number of bytes

19

Advertising