6.4.23 Force Feedback Data Read <<FBFC>> --- SCON-CA Only

(1) Function

The monitored data of load cell measurement (push force) is read.

The unit is 0.01 N.

(2) Query format

Field

Number of

characters

ASC II mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Register reading

Start address [H]

4

‘9’, ‘0’, ‘1’, ‘E’

Force feedback monitor

Number of registers [H]

4

‘0, ‘0, ‘0’, 2’

Reading address 901E

H

to 901F

H

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

17

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of

characters

ASC II mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Register reading

Number of data bytes [H]

2

‘0, ‘4’

Reading 2 register = 4 bytes

Data [H]

8

Position number status

Current push force [N]

Unit: 0.01 N

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

19