6. Modbus

ASCII

190

Modbus

6.4.2 Alarm Detail Description Reading <<ALAO, ALCO, ALTO>>

(1) Function

This bit reads the alarm codes, alarm detail codes and alarm occurrence time that last occurred.

When any alarm is not issued, it is “0

H

”. [Refer to 4.3.2 (1) to (3) for detail]

(2) Query format

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Register reading

Start address [H]

4

‘0’, ‘5’, ‘0’, ‘0’

Alarm detail code

Number of registers [H]

4

‘0’, ‘0’, ‘0’, ‘6’

Reading addresses 0500

H

to 0505

H

Error check [H]

2

LRC calculation result

Trailer

4

‘CR’, ‘LF’

Total number of bytes

17

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Register reading

Number of data bytes [H]

2

‘0’, ‘C’

Reading 6 registers = 12

bytes

Data 1 [H]

8

Alarm detail code

Alarm address

Alarm detail code(0500

H

) [Hex]

Alarm address(0501

H

) [Hex]

Data 2 [H]

8

Alarm code

Alarm code [Hex]

Data 3 [H]

8

Alarm occurrence

time

(Note1)

Alarm occurrence time

[Hex]

Error check [H]

2

‘CR’, ‘LF’

Trailer

2

Silent interval

Total number of bytes

35

Note 1 The contents of data differ for the case when the model is equipped with RTC (calendar)

function and RTC is effective [1] and the case when RTC is ineffective or the model is not

equipped with RTC [2].ᴾ

[1] It shows the alarm occurrence time.

[2] It shows the time [msec] passed since the power was

turned on.ᴾ