6. Modbus

ASCII

195

Modbus

(4) Query sample

A sample query that reads the Total moving distance (addresses 8402

H

to 8403

H

) of a controller with

axis No. 0 is shown below.

Query: 0138402000274 [CR][LF]

Field

ASCII mode

fixed character string

Converted ASCII code

data [H]

Header

‘:’

3A

Slave address

‘0’, ‘1’

3031

Function code

‘0’, ‘3’

3033

Start address

‘8’, ‘4’, ‘0’, ‘2’

38343030

Number of registers

‘0’, ‘0’, ‘0’, ‘2’

30303032

Error check

‘7’, ‘4’ (in accordance with

CRC calculation)

3734

Trailer

‘CR’, ‘LF’

0D0A

The response to the query is as follows.

Response: 01036040000409E1A[CR][LF]

Field

ASCII mode

fixed character string

Converted ASCII code

data [H]

Header

‘:’

3A

Slave address [H]

‘0’, ‘1’

3031

Function code [H]

‘0’, ‘3’

3033

Number of data bytes [H] ‘0’, ‘4’

3034

Data 1 [H]

‘0’, ‘0’, ‘0’, ‘0’

30303030

Data 2 [H]

‘4’, ‘0’, ‘9’, ‘E’

34303945

Error check [H]

‘1’, ‘A’ (in accordance with

LRC calculation)

3141

Trailer

‘CR’, ‘LF’

0D0A

The Total moving distance is “0000409E

H

” o Convert into decimal number o 16542 m

Note The data of the response example is simply an example and will vary depending on various

conditions.