6. Modbus

ASCII

275

Modbus

Note As soon as a position number is written to this register, the actuator starts moving. The

CSTR (start signal) is not required.

A response message to be sent following a successful change should be the same as the query.

[3] Move to position No. 1 using the position number specification register (address 0D03

H

).

Before this operation, perform the operation in example [1] above to complete a home return.

Query (Silent intervals are inserted before and after the query.)

First time

01 06 0D 03 00 01 E8

--- Specify position No. 1

Second time

01 06 0D 00 10 00 DC

--- Turn OFF the CSTR (start signal)

Third time

01 06 0D 00 10 08 D4

--- Turn ON the CSTR (start signal)

Field

ASCII mode 8-bit data

Converted ASCII

code data [H]

Start

‘:’

3A

Slave address [H]

‘0’, ‘1’

3031

Function code [H]

‘0’, ‘6’

3036

Start address [H]

First time: ‘0’, ‘D’, ‘0’, ‘3‘

Second time: ‘0’, ‘D’, ‘0’, ‘0’

Third time: ‘0’, ‘D’, ‘0’, ‘0‘

30443033

30443030

30443030

Changed data [H]

First time: ‘0’, ‘0’, ‘0’, ‘1’

Second time: ‘1’, ‘0’, ‘0’, ‘0’

Third time: ‘1’, ‘0’, ‘0’, ‘8’

30303031

31303030

31303038

Error check [H]

First time: ‘E’, ‘8’(in accordance with CRC

calculation)

Second time: ‘D’, ‘C’(in accordance with

CRC calculation)

Third time: ‘D’, ‘4’(in accordance with CRC

calculation)

4538

4443

4434

End

‘CR’, ‘LF’

0D0A

Note To keep the previous status, send the previous status even if there is no change. As in the

example above, keep the servo ON bit as 1 at home return as well.

If the change is successful, the response message will be the same as the query.