5. Modbus RTU

112

Modbus

(4) Query sample

A sample query that reads the expansion system status register (address 9015

H

) of a controller of

axis No. 0 is shown below.

z

Query (silent intervals are inserted before and after the query)

01 03 90 15 00 01 B8 CE

Field

RTU mode

8-bit data

Start

Silent interval

Slave address [H]

01

Function code [H]

03

Start address [H]

9015

Number of registers [H] 0001

Error check [H]

B8CE (in accordance with

CRC calculation)

End

Silent interval

The response to the query is as follows.

z

Response (silent intervals are inserted before and after the response)

01 03 02 01 00 B9 D4

Field

RTU mode

8-bit data

Start

Silent interval

Slave address [H]

01

Function code [H]

03

Number of data bytes [H] 02 (2 bytes = 1 registers)

Data 1 [H]

01 00

Error check [H]

B9D4 (in accordance with CRC calculation)

End

Silent interval

Note The data of the response example is simply an example and will vary depending on

various conditions.