Modbus – IAI America ROBO Cylinder Series User Manual

Page 86

Advertising
background image

5. Modbus RTU

78

Modbus

(4) Query sample

A sample query that reads the current position (addresses 9000

H

to 9001

H

) of a controller with axis

No. 0 is shown below.

z

Query (silent intervals are inserted before and after the query)

01 03 90 00 00 02 E9 0B

Field

RTU mode

8-bit data

Start

Silent interval

Slave address [H]

01

Function code [H]

03

Start address [H]

9000

Number of registers [H] 0002

Error check [H]

E90B (in accordance with

CRC calculation)

End

Silent interval

The response to the query is as follows.

z

Response (silent intervals are inserted before and after the response)

01 03 04 00 00 0B FE 7C 83

Field

RTU mode

8-bit data

Start

Silent interval

Slave address [H]

01

Function code [H]

03

Number of data bytes [H] 04 (4 bytes = 2 registers)

Data 1 [H]

00 00

Data 2 [H]

0B FE

Error check [H]

7C83 (in accordance with CRC calculation)

End

Silent interval

The current position is “00000BFE

H

” o Convert into decimal number o 3070 (x 0.01 mm) o

The current position is 30.7 mm.

Example 2) : If the current position is read “FFFFFFF5

H

” (negative position) o

FFFFFFFF

H

– FFFFFFF5

H

+ 1 (make sure to add 1) o

Convert into decimal number o 11 (x 0.01 mm) o

The current position is -0.11 mm

Note The data of the response example is simply an example and will vary depending on

various conditions.

Advertising