background image

4. Communicationn

46

Modbus

(15) Data of system status registers (Address = 9008

H

) (STAT)

Bit

Symbol

Name

Function

31

BATL

Absolute Battery Voltage

Drop

(for SCON only)

0: In normal conditionᴾ ᴾ

1: Battery voltage drop

It becomes 1 once the voltage of the absolute battery reaches below the

alarm level. The operation of the axes can be held even if this bit is

showing 1 as far as Critical Failure Status Bit in Device Status Register 1

is showing 0.

30 to 18

-

Cannot be used

17

ASOF Auto servo OFF

0: Normal

1: Auto servo OFF

If “Auto servo OFF delay time” is set with a parameter of the RC

controller, this bit becomes 1 when the servo is turned OFF

automatically after the specified time has elapsed following the position

complete.

16

AEEP

Nonvolatile memory

being accessed

0: Normal

1: Nonvolatile memory being accessed

This bit turns 1 as soon as the nonvolatile memory in the RC controller is

accessed to read or write the controller’s parameter position table, etc.

The bit becomes 0 when the access is completed or a timeout error

occurs.

15 to 5

-

Cannot be used

4

RMDS Operation mode status

0: AUTO mode

1: MANU mode

This bit becomes 1 when the RC controller is in the MANU mode.

Note that the controller is always in the MANU mode in cases of models

not equipped with an operation mode switch (ERC2, PCON-SE/CY and

ACON-SE/CY).

3

HEND Home return completion

status

0: Home return not yet complete

1: Home return completion

This bit will become 1 when home return is completed. In case the

absolute specification is set, the bit is set to 1 from the startup if absolute

reset has been completed.

If a movement command is issued while this bit is 0, an alarm will

generate.

2

SV

Servo status

0: Servo OFF

1: Servo ON

The servo ON status is indicated. After a servo ON command is issued,

this bit will remain 0 until the servo ON delay time set by a parameter

elapses.

If the servo cannot be turned ON for some reason even after a servo ON

command is received, this bit will remain 0.

The RC controller does not accept any movement command while this

bit is 0.

1

SON

Servo command status

0: Servo OFF

1: Servo ON

This bit indicates the servo ON/OFF command status.

This bit will turn 1 when the following conditions are met:

x

The EMG status bit in device status register 1 is 0.

[Refer to 5.3.11 or 6.4.11.]

x

The major failure status bit in device status register 1 is 0.

[Refer to 5.3.11 or 6.4.11.]

x

The enable status bit in device status register 2 is 1.

[Refer to 5.3.12 or 6.4.12.]

x

The auto servo OFF status in the system status register is 0.

[Refer to 5.3.14 or 6.4.14.]

0

MPOW Drive source ON

0: Drive source cut off

1: Normal

This bit will turn 0 when the motor drive-source cutoff terminal is

released.