Modbus – IAI America ROBO Cylinder Series User Manual

Page 109

Advertising
background image

5. Modbus RTU

101

Modbus

5.3.17 Deviation Reading <<DEVI>>

(1) Function

This bit reads the deviation over a 1-ms period between the position command value and the

feedback value (actual position). The unit is pulse. The number of pulses per one motor revolution

in mechanical angle varies depending on the encoder used.

(2) Query format

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Start address [H]

2

900E

Deviation monitor

Number of registers [H]

2

0002

Reading addresses 900E

H

to

900F

H

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

8

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Number of data bytes [H]

1

04

Reading 2 registers = 4 bytes

Data [H]

4

Deviation monitor

Deviation monitor [Hex]

The unit is pulse.

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

9