3. Specifications

20

Modbus

(3) SIO converter (vertical specification: RCB-TU-SIO-A, horizontal specification: RCB-TU-

SIO-B)

A RS232C œ RS485 converter

Fig. 3.3

~

Power supply and emergency stop terminal block (TB2)

x

EMG1 and EMG2: Discrete outputs of the emergency stop switch of the teaching

pendant

EMG1 and EMG2 are connected to the emergency stop switch of

the teaching pendant when the PORT switch is set to ON; EMG1

and EMG2 are short circuited when the switch is set to OFF.

x

24 V: Supply +24 V power (current consumption 0.1 A or less)

x

0 V: Supply 0 V power (use common 0 V for all 24 V DC-supplied controllers).

x

FG: A terminal to which FG is connected

* Compatible wires: Single wire: ‡ 0.8 to 1.2 mm

Twisted wire: AWG18 to 20 (strip length 10 mm)

~

Link connection terminal block (TB1)

A connector for link connection with an RC controller

x

A: Connect to pin 1 (SGA) of the communication

connector of the RC controller

x

B: Connect to pin 2 (SGB) of the communication

connector of the RC controller

~

D-sub 9 pin connector

A connector for connection with the master (host) side

~

Mini DIN8 pin connector

A connector for connection with teaching pendant or PC software

~

PORT switch

x

ON: A teaching tool is used.

x

OFF: A teaching tool is not used.

~

LED for monitoring (LED1 and LED2)

x

LED1: Turns on/flashes when the RC controller is transmitting

x

LED2: Turns on/flashes when the master (host) side is transmitting

~

Link connector (J4 and J5)

Connectors for link connection with an RC controller

An optional link cable (CB-RCB-CTL002) can be connected as is.

Link connection terminal block

(TB1)

LED for monitoring

(LED1 and LED2)

D-sub 9-pin connector

Link connector (J4 and J5)

Power supply and

emergency stop terminal block

(TB2)

PORT switch

Mini DIN8 pin connector

Terminal screw: M3Ч6

6.4