5. Modbus RTU

139

Modbus

(4) Query sample

[1] A sample query that makes a controller of axis No. 0 jog is shown below.

Query (silent intervals are inserted before and after the query)

01 05 04 17 FF 00 3D 0E

Field

RTU mode

8-bit data

Start

Silent interval

Slave address [H]

01

Function code [H]

05

Start address [H]

0417

Changed data [H]

FF00

Error check [H]

3D0E (in accordance with

CRC calculation)

End

Silent interval

If the change is successful, the response message will be the same as the query.

[2] A sample query that makes a controller of axis No. 0 inch is shown below.

Query (silent intervals are inserted before and after the query)

First time

01 05 04 17 FF 00 3D 0E ··· Perform inching movement

Second time 01 05 04 17 00 00 7C FE ··· Restore the normal status

Field

RTU mode

8-bit data

Start

Silent interval

Slave address [H]

01

Function code [H]

05

Start address [H]

0417

Changed data [H]

First time: FF00

Second time: 0000

(Restore the normal status)

Error check [H]

First time: 3D0E

(in accordance with CRC calculation)

Second time: 7CFE

(in accordance with CRC calculation)

End

Silent interval

If the change is successful, the response message will be the same as the query.