Modbus – IAI America ROBO Cylinder Series User Manual

Page 282

Advertising
background image

6. Modbus

ASCII

274

Modbus

(5) Query sample

Examples of different operations are shown in [1] to [3] below.

[1] A sample query that turns the servo of a controller of axis No. 0 on and then executes home

return operation is performed.

Query

First time

01 06 0D 00 10 00 DC --- Servo ON

Second time 01 06 0D 00 10 10 CC --- Home return

Field

ASCII mode 8-bit data

Converted ASCII

code data [H]

Start

‘:’

3A

Slave address [H]

‘0’, ‘1’

3031

Function code [H]

‘0’, ‘6’

3036

Start address [H]

‘0’, ‘D’, ‘0’, ‘0’

30443030

Changed data [H]

First time: ‘1’, ‘0’, ‘0’, ‘0’

Second time: ‘1’, ‘0’, ‘1, ‘0’

31303030

31303130

Error check [H]

First time: ‘D’, ‘C’ (in accordance with CRC

calculation)

Second time: ‘C’, ‘C’ (in accordance with

CRC calculation)

4443

4343

End

‘CR’, ‘LF’

0D0A

Note 1 Home return is not performed even if 1010

H

is sent to change the data while the servo is

OFF (refer to the timing chart at startup of each RC controller).

Note 2 To keep the previous status, send the previous status even if there is no change. As in the

example above, keep the servo ON bit as 1 at home return as well.

If the change is successful, the response message will be the same as the query.

[2] Move to position No. 1 using the position movement specification register (address 9800

H

).

Before this operation, perform the operation in example [1] above to complete a home return.

Query (Silent intervals are inserted before and after the query.)

01 06 98 00 00 01 60

Field

ASCII mode 8-bit data

Converted ASCII

code data [H]

Start

‘:’

3A

Slave address [H]

‘0’; ‘1’

3031

Function code [H]

‘0, ’ ‘6’

3036

Start address [H]

‘9’, ‘8’, ‘0’, ‘0’

39383030

Changed data [H]

‘0’, ‘0’, ‘0’, ‘1’

30303031

Error check [H]

‘6’, ‘0’ (in accordance with CRC calculation) 3630

End

‘CR’, ‘LF’

0D0A